Eco-Type Gauging Hatch

Eco-Type Gauging Hatch

Eco-Type Gauging Hatch — DN200, ASME B16.5 Class 150 RF

The WANAN eco-type gauging hatch is a vapour-tight gauging port for atmospheric storage tanks. It lets the operator gauge liquid level, measure water bottom, take a temperature reading or draw a sample without releasing product vapour to atmosphere — protecting both the environment and the people working on the tank roof from hydrocarbon exposure.

The body is a single ductile iron casting with an ASME B16.5 Class 150 raised-face flange. The cover is counter-weighted and spring-assisted: it opens through a 90° arc, stays open while the tape is lowered, and closes onto a PTFE seat to restore the vapour seal. Every hatch is tightness-tested at +6 000 Pa before delivery.

DN200 (8″)
Nominal size
CL150 RF
ASME B16.5 flange
+6 000 Pa
Tightness test
SS304 / PTFE
Wetted trim

Why replace an open gauge hatch?

Every open gauging hatch on a tank roof is an uncontrolled vapour connection. Hydrocarbons escape each time the cover is lifted for a level reading, a water-bottom check or a sample, and the vapour cloud collects around the operator’s position on the roof. Beyond the product loss, that leakage is the usual cause of odour complaints around tank farms and of failures in emission inspections.

The eco-type hatch closes that path. The cover seals on a PTFE gasket, the guide slot lets the tape pass without propping the cover open, and the counterweight keeps the cover clear of the operator’s hands during the measurement. The result is a gauging point that behaves like a closed system in normal service, while remaining as quick to use as an open hatch.

Construction and working principle

The lower body carries the tank flange and the seating face. A PTFE gasket sits in the body groove and a matching PTFE cover seal is recessed into the cover plate, so the two sealing faces close metal-to-PTFE rather than metal-to-metal. The cover plate hinges on a swivel shaft with a lifting spindle; a counterweight and an SS304 chain hold it open through the full 90° arc. The slide slot in the cover is sized for standard gauging tapes and sampling bottles, and a guide plate keeps the tape centred on the dip point.

Because the wetted parts are SS304 and PTFE, the hatch suits crude oil, gasoline, diesel, jet fuel, solvents, aromatics and alcohols, as well as corrosive service where a painted carbon steel hatch would degrade. The ductile iron body provides the flange stiffness and impact resistance needed on a tank roof at a fraction of the cost of a fully stainless body.

Technical specifications

參數規格
產品Eco-type gauging hatch (vapour-tight gauge hatch cover)
Nominal sizeDN200 (8″), other sizes on request
FlangeASME B16.5 Class 150 raised face, 8-Φ22 bolt holes; JIS / DIN / EN on request
Tightness+6 000 Pa air test on every unit, no leakage permitted
Body / cover materialDuctile iron body and cover plate, stainless steel wetted trim
Wetted trimSS304 guide plate, slide slot, chain, hinge and fasteners; PTFE seat and cover seal
Cover opening90° arc, counter-weighted, spring assisted, chain retained
Cover OD / neck ODΦ345 mm / Φ298.5 mm
整體尺寸L 660 mm × H 340 mm
服務Atmospheric storage tanks — crude, gasoline, diesel, jet fuel, solvents, aromatics, alcohols
Drawing referenceHN-2021-A

Component materials

項目元件材質
1 / 6Body (lower) / cover plateDuctile iron
2 / 4Body gasket / cover sealPTFE
3 / 9Handwheel / swivel shaftDuctile iron
5 / 7 / 8Seal cover / slide slot / lifting spindleSS304
10Valve plug with O-ring, Φ10Ductile iron
11 / 12 / 14 / 15 / 16 / 17 / 18Guide plate, swivel shaft, retaining ring, pin Φ4×20, chain, plug, housingSS304
13Wheel axle M12×90Steel, zinc plated

Other sizes, materials and flange standards can be quoted on request.

Where it is used

  • Refinery and terminal tank farms — fixed roof and floating roof tanks handling crude oil, gasoline, diesel and jet fuel.
  • Petrochemical and chemical storage — solvents, aromatics, alcohols and other volatile products where vapour release must be controlled.
  • New tank construction — supplied as the roof gauging nozzle closure, matched to the nozzle flange schedule.
  • Retrofit of open hatches — replacement of leaking or non-sealing gauging hatches during tank turnaround, without modification of the roof nozzle.

安裝

  1. Mount the hatch vertically on the tank roof gauging nozzle — mating flange ASME B16.5 Class 150 RF, DN200.
  2. Tighten the eight bolts evenly in a cross pattern so that the PTFE gasket is compressed uniformly around the full face.
  3. Check that the cover swings freely through its full arc, that the counterweight holds it open, and that the chain is correctly anchored to the body.
  4. Carry out a leak check at the flange joint and around the cover seal before the tank is put back into service.

運作與維護

  1. Release the latch and lift the cover — the counterweight holds it open through 90°.
  2. Lower the gauging tape or sampling bottle through the slide slot; the guide plate keeps the tape centred on the dip point.
  3. Gauge level, measure water bottom, take temperature or draw the sample as required.
  4. Close the cover firmly after each operation so that the PTFE seal is re-established.
  5. Inspect the PTFE gasket and cover seal at each tank inspection and replace them if they are cut, compressed or contaminated.

常見問題

What is the difference between an eco-type gauging hatch and a standard gauge hatch?

An eco-type hatch seals on a PTFE gasket and is tested for tightness at +6 000 Pa, so vapour cannot escape when the cover is closed. A conventional open hatch has a loose cover and vents the tank continuously; it cannot pass an emission inspection on a volatile product.

Does the hatch interfere with level gauging or sampling?

No. The slide slot in the cover is sized for standard gauging tapes and sampling bottles, and the guide plate keeps the tape centred. The counterweighted cover stays open through 90° so the operator has both hands free for the measurement.

Which flange standard is supplied as standard?

ASME B16.5 Class 150 raised face, DN200, with 8-Φ22 bolt holes — 660 mm overall length, 340 mm overall height. JIS, DIN and EN drilling, other sizes and other body materials are available on request.

Can the hatch be fitted to an existing tank?

Yes, provided the roof nozzle flange matches ASME B16.5 Class 150 RF. The hatch is bolted onto the existing nozzle during a tank shutdown; no work inside the tank is needed.

What materials are in contact with the product vapour?

SS304 for the guide plate, slide slot, chain, hinge parts and fasteners, with PTFE for the body gasket and cover seal. The ductile iron body is not exposed to the product because the PTFE gasket seals against the flange face.

索取報價

Send us the tank size, roof nozzle flange standard, product handled and the quantity required, and we will return a model code, dimensional drawing and price. A two-page product data sheet with the full component and dimension tables can be downloaded here: Eco-Type Gauging Hatch — Product Data Sheet (PDF).

電子郵件: info@wanantec.com · 電話:+86-27-8194-8788 · 請聯絡我們的工程團隊

相關產品

常見問題

閉環取樣器是一種安全裝置,用於從管線或儲存槽中採集液體樣本,同時避免操作人員接觸危險化學品。Wanan 閉環取樣器符合 API MPMS 8.2 標準,採用密封設計,可將吹掃液回輸至工藝系統,從而消除揮發性有機化合物(VOC)的排放。.

Wanan 防火焰阻隔器已通過 ISO 16852、ATEX(歐洲爆炸性環境指令)及 EN 12874 標準認證。我們提供適用於 IIA、IIB 及 IIC 氣體類別的型式測試報告。 所有產品均於我們通過 ISO 9001:2015 認證的廠房內製造。.

是的。Wanan Technology 是中國石化、中國石油、中國海洋石油(中國)、埃克森美孚、盧克石油(俄羅斯)、埃尼(義大利)、哈薩克斯坦國家石油天然氣公司(哈薩克斯坦)以及委內瑞拉國家石油公司(PDVSA)等企業的註冊合格供應商。.

Wanan Technology 在德國、美國及中國設有製造基地。我們亦於阿聯酋設有庫存及銷售服務中心,以提供快速交貨服務,滿足中東及全球客戶的需求。.

萬安科技的密閉式取樣器適用於石化、天然氣、煉油及儲罐場等產業中,涉及有毒及危險介質的液體取樣情境。該產品符合 API MPMS 8.2 標準,可防止操作人員接觸危險物質,並符合 HSE 環境排放要求。.

A:標準產品將於訂單確認後 2 至 4 週內出貨。客製化解決方案通常需時 6 至 8 週,具體時間視規格複雜程度而定。針對緊急專案,我們可應要求提供加急生產服務——請向我們的銷售團隊提供您的時程安排,我們將據此擬定生產計畫。.

A:我們的產品符合主要國際標準,包括 ISO 3170(石油取樣)、API MPMS 8.1/8.2、爆炸性環境的 ATEX 標準、ASME 以及 EAC。樣品氣瓶可提供 DOT 及 TPED 認證。我們會隨每筆訂單提供完整的認證文件及材料測試證書。.

A:是的。我們提供樣品供您評估使用。經您確認無誤後,我們將寄送一至兩件樣品,以便您在決定下大宗訂單前,先確認產品與您的應用需求、材料及現場條件是否相容。運費將視目的地而定。.